Expert Advice Better Batteries Best Prices, everyday!
Acacia Ridge: 07 3194 8805
Ipswich: 07 3736 0297
Acacia Ridge
Ipswich
Expert Advice Better Batteries Best Prices, everyday!
SKU: 12803

USL16HCXC2 420Ah US Deep Cycle Battery (Flooded Deep Cycle Battery)

$763.00

In Stock Please note that products available In Stock are generally available within 1 business day for pick-up or delivery.

Shipping Options

  • Free Delivery in Brisbane

    & surrounding areas
  • Proudly Australian

    Easy to claim
  • Manufacturer's Warranty

    Owned and Operated
Category: Tags: , Brand:

Description

Application: Wherever Deep Cycle 6-volt batteries are needed. (Without Handles)

Dimensions: 11-7/8 (302)L x 7-1/8 (181)W x 16-3/4 (425)H (With Handles) 12-7/16 (315)L x 7-1/8 (181)W x 16-3/4 (425)H

Type: Flooded Lead Acid (FLA) non-sealed.

Case material: Polypropylene / Heat Sealed

 

US L16HC XC2  6V 420 Ah 

315 L x 181 W x 425 H

Charging Instructions:

Following is the charging recommendation and charging profile using 2 stage chargers for US Battery deep cycle products. *Equalization and float charge modes are not considered to be one of the stages in a charging profile. 1. Bulk Charge Constant current @~10% of C/20 Ah in amps to 2.45+/-0.05 volts per cell (e.g. 7.35 volts +/-0.15 volts per 6 volt battery) 2. Absorption Charge Constant voltage (2.45+/-0.05 vpc) to 3% of C/20 Ah in amps then hold for 2-3 hours and terminate charge Charge termination can be by maximum time (2-4 hr) or dV/dt (4 mv/cell per hour) • (Optional Float Charge) Constant voltage 2.17 vpc (6.51 volts per 6 volt battery) for unlimited time • Equalization Charge Constant voltage (2.55+/-0.05 vpc) extended for 1-3 hours after normal charge cycle (repeat every 30 days) Notes: Charge time from full discharge is 9-12 hours. Absorption charge time is determined by the battery but will usually be ~3 hours at 2.45 volts per cell. Float time is unlimited at 2.17 volts per cell. Specific gravity at full charge is 1.270 minimum

Get a Free Quote

  • This field is for validation purposes and should be left unchanged.